Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/23199
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJin-Chang Lai-
dc.contributor.authorWin-Jet Luo-
dc.contributor.authorJyun-Yi Wu-
dc.contributor.authorDini Faridah-
dc.contributor.authorChia-Ming Lin-
dc.contributor.authorFikri Rahmat Fasya-
dc.contributor.authorMuhammad Nuriyadi-
dc.contributor.authorWen-Bin Ng-
dc.date.accessioned2019-11-27T09:20:46Z-
dc.date.available2019-11-27T09:20:46Z-
dc.date.issued2018-04-
dc.identifier.citationLai, J. C., Luo, W. J., Wu, J. Y., Faridah, D., Lin, C. M., Fasya, F. R., … Ng, W. Bin. (2018). Performance analysis of single-stage air source heat pump utilizing indirect vapor injection design. Advances in Mechanical Engineering, 10(4), 1–12.en_US
dc.identifier.issn1687-8132-
dc.identifier.urihttps://doi.org/10.1177/1687814018767487-
dc.identifier.urihttps://journals.sagepub.com/doi/full/10.1177/1687814018767487-
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85046639740&doi=10.1177%2f1687814018767487&origin=inward&txGid=1411e1011c2224e00cfb7029b9b01aff-
dc.identifier.urihttp://ir.unikl.edu.my/jspui/handle/123456789/23199-
dc.description.abstractThis study investigated the performance of a single-stage scroll compressed air source heat pump coupled with a flash tank indirect vapor injection. In the refrigerant circulating piping of the heat pump, an indirect vapor injection piping connecting a flash tank at the refrigerant outlet of a condenser and the suction of a scroll compressor was designed. By the indirect refrigerant vapor injection from the flash tank, the saturation pressure and temperature of the refrigerant (R134a) in the evaporator can be raised and the sub-cooling of the refrigerant at the inlet of expansion valve can be enlarged as well. Thus, energy consumption of the compressor can be reduced and cooling capacity of the evaporator can be boosted. It was found that the suitable amount of indirect vapor refrigerant strongly depends on the operational environmental temperatures. By adjusting the suitable indirect vapor injection volume into the compressor, the performance of the heat pump was enhanced. In this study, a suitable indirect vapor injection volume was found and 5~15% performance increments can be obtained while the heat pump operated under ambient temperatures in a range from 5°C to 35°C.en_US
dc.language.isoenen_US
dc.publisherSageen_US
dc.subjectAir source heat pumpen_US
dc.subjectflash tanken_US
dc.subjectindirect vapor injectionen_US
dc.subjectcoefficient of performanceen_US
dc.subjectvalve openingen_US
dc.titlePerformance analysis of single-stage air source heat pump utilizing indirect vapor injection designen_US
dc.typeArticleen_US
Appears in Collections:Journal Articles