dc.date.issued2021-01-
dc.identifier.citationMohd Afzal, Mohd Muddassir, Alarifi, A., & Ansari, M. T. (2021). Box-Behnken Assisted Validation and Optimization of an RP-HPLC Method for Simultaneous Determination of Domperidone and Lansoprazole. Separations,8(1), 5. https://doi.org/10.3390/separations8010005en_US
dc.identifier.issn22978739-
dc.identifier.urihttps://doi.org/10.3390/separations8010005-
dc.identifier.urihttp://hdl.handle.net/123456789/26056-
dc.description.abstractA highly specific, accurate, and simple RP-HPLC technique was developed for the real time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 µm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.en_US
dc.language.isoenen_US
dc.publisherMDPI AGen_US
dc.subjectLansoprazoleen_US
dc.subjectDomperidoneen_US
dc.subjectMethod validationen_US
dc.subjectBox–Behnkenen_US
dc.subjectChromatographyen_US
dc.titleBox-behnken assisted validation and optimization of an RP-HPLC method for simultaneous determination of domperidone and lansoprazoleen_US
dc.typeArticleen_US
Appears in Collections:Journal Articles



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.