Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/24883
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlhamrouni, Ibrahim-
dc.contributor.authorHanafi, F. N.-
dc.contributor.authorSalem, Mohamed-
dc.contributor.authorA. Rahman, Nadia H.-
dc.contributor.authorAwang Jusoh-
dc.contributor.authorSutikno, Tole-
dc.contributor.authorUniKL BMI-
dc.date.accessioned2021-04-10T04:15:40Z-
dc.date.available2021-04-10T04:15:40Z-
dc.date.issued2020-
dc.identifier.citationIbrahim Alhamrouni, F. N. Hanafi, Mohamed Salem, Nadia H. A. Rahman, Awang Jusoh, Tole Sutikno, Design of shunt hybrid active power filter for compensating harmonic currents and reactive power, Volume 18, Issue 4, 2020, DOI: http://dx.doi.org/10.12928/telkomnika.v18i4.15156en_US
dc.identifier.issn16936930-
dc.identifier.urihttp://hdl.handle.net/123456789/24883-
dc.descriptionThe article is indexed by Scopusen_US
dc.description.abstractFor the past two decades, tremendous advancements have been achieved in the electricity industry. The usage of non-linear loads in the daily life has affected the power quality of the system and caused the presence of harmonics. To compensate the harmonic currents and reactive power in the system, the design of shunt hybrid active power filter has been proposed in this research. The design of the filter has included several control systems of instantaneous active and reactive power (p-q) theory and PI controller to investigate the performance of the filter. The robustness of the designed hybrid power filter has also been benchmarked with the other filter topologies available in literature. The hybrid power filter will combine passive power filter and active power filter configurated in shunt connection. The result of this research showed that the total harmonic distortion analyzed is below than 5% according to IEEE-519 standard requirements and reactive power is compensated proved by the increase in power factor. The shunt hybrid active power filter is designed, and simulation result is analyzed by using MATLAB-Simulink environment. © 2020, Universitas Ahmad Dahlan.en_US
dc.language.isoenen_US
dc.publisherUniversitas Ahmad Dahlanen_US
dc.relation.ispartofseries;Volume 18, Issue 4, 2020, Pages 2148-2157-
dc.subjectHarmonicen_US
dc.subjectHybrid active filteren_US
dc.subjectP-q theoryen_US
dc.subjectPi controlleren_US
dc.subjectPower factor correctionen_US
dc.titleDesign of shunt hybrid active power filter for compensating harmonic currents and reactive poweren_US
dc.typeArticleen_US
dc.conference.nameTelkomnika (Telecommunication Computing Electronics and Control)en_US
dc.conference.year2020en_US
Appears in Collections:Journal Articles

Files in This Item:
File Description SizeFormat 
Design of shunt hybrid active power filter for compensating.pdf1.8 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.