DSpace Repository

Analysis on Four Derivative Waveforms of Photoplethysmogram (PPG) for Fiducial Point Detection

Show simple item record

dc.contributor.author Mohd Zubir Suboh
dc.contributor.author Rosmina Jaafar
dc.contributor.author Nazrul Anuar Nayan Nayan
dc.contributor.author Noor Hasmiza Harun
dc.contributor.author Mohd Shawal Faizal Mohamad
dc.contributor.author UniKL BMI
dc.date.accessioned 2023-05-29T07:58:04Z
dc.date.available 2023-05-29T07:58:04Z
dc.date.issued 2022-06-30
dc.identifier.citation Mohd Zubir Suboh, Rosmina Jaafar, Nazrul Anuar Nayan, Noor Hasmiza Harun, Mohd Shawal Faizal Mohamad (2022). Analysis on Four Derivative Waveforms of Photoplethysmogram (PPG) for Fiducial Point Detection. Frontiers in Public Health, Volume 10. http://dx.doi.org/10.2139/ssrn.4075793 en_US
dc.identifier.issn 22962565
dc.identifier.uri http://hdl.handle.net/123456789/27860
dc.description This article is indexed by Scopus en_US
dc.description.abstract Fiducial points of photoplethysmogram (PPG), first derivative PPG (VPG), and second derivative PPG (APG) are essential in extracting numerous parameters to diagnose cardiovascular disease. However, the fiducial points were usually detected using complex mathematical algorithms. Inflection points from derivatives waveforms are not thoroughly studied, whereas they can significantly assist in peak detection. This study is performed to investigate the derivative waveforms of PPG and use them to detect the important peaks of PPG, VPG, and APG. PPGs with different morphologies from 43 ischemic heart disease subjects are analyzed. Inflection points of the derivative waveforms up to the fourth level are observed, and consistent information (derivative markers) is used to detect the fiducial points of PPG, VPG, and APG with proper sequence. Moving average filter and simple thresholding techniques are applied to detect the primary points in VPG and the third derivative waveform. A total of twelve out of twenty derivative markers are found reliable in detecting fiducial points of two common types of PPG. Systolic peaks are accurately detected with 99.64% sensitivity and 99.38% positive predictivity using the 43 IHD dataset and Complex System Laboratory (CSL) Pulse Oximetry Artifact Labels database. The study has introduced the fourth derivative PPG waveform with four main points, which are significantly valuable for detecting the fiducial points of PPG, VPG, and APG. en_US
dc.language.iso en en_US
dc.publisher Frontiers in Public Health en_US
dc.subject acceleration plethysmogram (APG) en_US
dc.subject photoplethysmogram (PPG) en_US
dc.subject PPG derivatives en_US
dc.subject PPG fiducial points en_US
dc.subject velocity plethysmogram (VPG) en_US
dc.title Analysis on Four Derivative Waveforms of Photoplethysmogram (PPG) for Fiducial Point Detection en_US
dc.type Article en_US
dc.conference.name Frontiers in Public Health, Volume 10, 30 June 2022, Article number 920946 en_US
dc.conference.year 2022 en_US


Files in this item