DSpace Repository

Box-behnken assisted validation and optimization of an RP-HPLC method for simultaneous determination of domperidone and lansoprazole

Show simple item record

dc.contributor.author Mohd Afzal
dc.contributor.author Mohd. Muddassir
dc.contributor.author Abdullah Alarifi
dc.contributor.author Mohammed Tahir Ansari
dc.contributor.author (UniKL RCMP)
dc.date.accessioned 2022-10-20T03:12:44Z
dc.date.available 2022-10-20T03:12:44Z
dc.date.issued 2021-01
dc.identifier.citation Mohd Afzal, Mohd Muddassir, Alarifi, A., & Ansari, M. T. (2021). Box-Behnken Assisted Validation and Optimization of an RP-HPLC Method for Simultaneous Determination of Domperidone and Lansoprazole. Separations,8(1), 5. https://doi.org/10.3390/separations8010005 en_US
dc.identifier.issn 22978739
dc.identifier.uri https://doi.org/10.3390/separations8010005
dc.identifier.uri http://hdl.handle.net/123456789/26056
dc.description.abstract A highly specific, accurate, and simple RP-HPLC technique was developed for the real time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 µm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations. en_US
dc.language.iso en en_US
dc.publisher MDPI AG en_US
dc.subject Lansoprazole en_US
dc.subject Domperidone en_US
dc.subject Method validation en_US
dc.subject Box–Behnken en_US
dc.subject Chromatography en_US
dc.title Box-behnken assisted validation and optimization of an RP-HPLC method for simultaneous determination of domperidone and lansoprazole en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account