DSpace Repository

Physical factors investigation on surgical dexterity parameters using computer-based assessment system

Show simple item record

dc.contributor.author Cham, Y.K.,
dc.contributor.author Su, E.L.M.,
dc.contributor.author Yeong, C.F.,
dc.contributor.author Ahmmad, S.N.Z.,
dc.contributor.author Sood, S.,
dc.contributor.author Gandhi, A.
dc.contributor.author (UniKL MITEC)
dc.date.accessioned 2022-09-12T04:09:34Z
dc.date.available 2022-09-12T04:09:34Z
dc.date.issued 2021
dc.identifier.uri http://hdl.handle.net/123456789/25611
dc.description This article is index by Scopus en_US
dc.description.abstract Surgical dexterity is one of the crucial metrics for evaluating candidates during surgical residency training. Many factors influence surgical dexterity performance, but they are not studied in depth. Hence, the objective of this study is to investigate the correlation between factors and surgical dexterity performance with the aid of a computer-based assessment system. A custom data acquisition module was developed, namely the “Green Target Module,” to acquire positional data of hand movements from the subjects when controlling a cursor in a 3D virtual reality (VR) scene. The positional data were recorded and extracted into seven objective parameters, which are motion path length, the economy of movement, motion smoothness, motion path accuracy, motion path precision, endpoint accuracy, and endpoint precision. Body posture, magnification, and handedness were investigated to figure out a preferable setup for better performance. A total of thirty-four subjects from different surgical backgrounds were recruited for the experiments. Fourteen trials were recorded in each test, and every subject was required to complete eight tests with different experimental configurations. Results showed that endpoint accuracy while sitting was significantly better than standing. Using 10x magnification during surgical dexterity assessment showed significantly better performance outcomes than 1x magnification. Performing dexterity test using dominant hand also showed significantly better when compared to non-dominant hand en_US
dc.subject Manual dexterity; en_US
dc.subject assessment parameters; en_US
dc.subject assessment factors; en_US
dc.subject body posture; en_US
dc.subject visual magnification; en_US
dc.subject handedness en_US
dc.title Physical factors investigation on surgical dexterity parameters using computer-based assessment system en_US
dc.type Article en_US