DSpace Repository

Determination of phosphodiesterase type 5 enzyme (PDE-5) inhibitors and analogues as adulterants in selected herbal products using gas chromatography-electron impact-mass spectrometer (GC-EI-MS)

Show simple item record

dc.contributor.author Nur Azzalia Kamaruzaman
dc.contributor.author Mazlin Mohideen
dc.contributor.author Leong, Yin-Hui
dc.contributor.author Azaharudin Awang Ahmad
dc.contributor.author Norjuliana Mohd Noor
dc.contributor.author (UniKL RCMP)
dc.date.accessioned 2021-10-21T08:37:25Z
dc.date.available 2021-10-21T08:37:25Z
dc.date.issued 2020-12
dc.identifier.citation Nur Azzalia Kamaruzaman, Mazlin Mohideen, Leong, Y.-H., Azaharudin Awang Ahmad, Norjuliana Mohd Noor. (2020). Determination of Phosphodiesterase Type 5 Enzyme (PDE-5) Inhibitors and Analogues as Adulterants in Selected Herbal Products using Gas Chromatography–Electron Impact-Mass Spectrometer (GC-EI-MS). Baghdad Science Journal, 17(4), 1190-1197. https://doi.org/10.21123/bsj.2020.17.4.1190 en_US
dc.identifier.issn 20788665
dc.identifier.uri http://hdl.handle.net/123456789/25154
dc.description.abstract Sildenafil, tadalafil, and vardenafil are phosphodiesterase type 5 enzyme (PDE-5) inhibitors used for the treatment of male erectile dysfunction. This present study aims to investigate 55 herbal products indicated for men's sexual health from the Malaysian market for adulteration of PDE-5 inhibitors and analogues. The screening and identification of 20 PDE-5 inhibitors and analogues in herbal products of various forms (powder, capsules, tablets, and pastels) were conducted using gas chromatography-electron impact-mass spectrometer (GC-EI-MS). The analysis has shown that 19 herbal products were adulterated with PDE-5 inhibitors and analogues. Unique ion fragmentations and the presence of molecular ion serve as potential markers, and the limit of detection (LOD) was 0.1-5.0 μg/g. Ten PDE-5 inhibitors and analogues were randomly selected and successfully validated for simultaneous quantification, whereby the limit of quantitation (LOQ) was 5.0-50.0 μg/g with recoveries at 86.1-118.9%. The developed method of GC-EI-MS was shown to be simple, throughput, economical and had sufficient sensitivity to screen, identify and quantify PDE-5 inhibitors and analogues in herbal matrices. en_US
dc.language.iso en en_US
dc.publisher University of Baghdad en_US
dc.subject Adulteration en_US
dc.subject Chromatography–electron impact-mass spectrometer (GC-EI-MS), en_US
dc.subject Herbal products en_US
dc.subject Men’s sexual health en_US
dc.subject Phosphodiesterase type 5 enzyme (PDE-5) inhibitors en_US
dc.title Determination of phosphodiesterase type 5 enzyme (PDE-5) inhibitors and analogues as adulterants in selected herbal products using gas chromatography-electron impact-mass spectrometer (GC-EI-MS) en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account