dc.identifier.citation Zabariah Zakaria, Mohd Zahri Abdul Aziz, Noramaliza Mohd Noor (2020). Thermoluminescence Dosimetric Characteristics Of Fabricated Germanium (Ge) Doped Optical Fibres For Electron Beams Dosimetry: A Preliminary Study. [(Pencirian Dosimeter Pendar Gerlap Terma terhadap Gentian Optik Dop Germanium yang Difabrikasi bagi Pengukuran Dos dalam Pancaran Elektron: Sebuah Kajian Awal)]. Sains Malaysiana, Vol. 49 (Issue 8). DOI : 10.17576/jsm-2020-4908-20 en_US
dc.identifier.issn 01266039
dc.identifier.uri http://hdl.handle.net/123456789/25019
dc.description This article is indexed by Scopus en_US
dc.description.abstract The basic dosimetric favourable responses of tailored fabricated germanium (Ge) doped cylindrical optical fibres, make use of 2.3% mol have been extensively studied with clinical electron beams irradiation in terms of dose linearity, reproducibility, fading signals, minimum detectable dose (MDD), energy- and field size dependence. The irradiation was performed at the Radiotherapy Unit, Advanced Medical and Dental Institute (AMDI), which utilizes Elekta Synergy® linear accelerator (LINAC) at 6-, 9-, 12- and 15 MeV electron beam energies at specific doses ranging from 1 to 5 Gy. Thermoluminescence (TL) signals exhibited a linear dose-response overdose ranges, mean reproducibility with a coefficient of variation (CV) of better than 10% and no dependency with different field sizes at p > 0.05. The MDD values were typically 3.51 to 4.13 mGy. The minimum TL fading of the fabricated Ge-doped cylindrical optical fibres was reported favourably for 9 MeV electron beam at day of 74. en_US
dc.language.iso en en_US
dc.publisher Penerbit Universiti Kebangsaan Malaysia en_US
dc.subject Dose linearity en_US
dc.subject optical fibres en_US
dc.subject thermoluminescence (TL) en_US
dc.title Thermoluminescence dosimetric characteristics of fabricated germanium (Ge) doped optical fibres for electron beams dosimetry: A preliminary study en_US
dc.type Article en_US
dc.conference.name Sains Malaysiana Volume 49, Issue 8, August 2020, en_US
dc.conference.year 2020 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account